You do not have any products in your shopping cart yet.
DRU Lugo 80/2 RCH
DRU - Lugo 80/2 Eco Wave RCH
The DRU Lugo 80/2 Eco Wave is a high-quality, two-sided gas fire that is characterised by its modern design and impressive fire display. With a width of 80 cm, this fireplace offers a log fire display that is visible from different angles, making it ideal for open-plan living spaces.
Special features:
Seamless design: there are no visible vents in the frame, creating a seamless connection between the glass window and the plinth. This creates a minimalist and elegant appearance.
Interior finishes: The interior can be finished in either matt black or mirrored ceraglass. The mirrored option reflects the flames, enhancing the visual depth of the fire.
Eco Wave technology: This innovative technology allows the flame pattern and gas consumption to be flexibly adjusted. This reduces energy consumption while retaining the atmosphere of a fully-fledged fire.
The DRU Lugo 80/2 Eco Wave is therefore not only a visual highlight, but also an efficient and environmentally friendly heating solution for modern living spaces.
Specifications
- Brand: DRU
- Energy efficiency class:

- Outout net G20 (G25) min. kW: 3,4 (2,8)
- Output net G20 (G25) max. kW: 6,9 (6,5)
- Model: Built in
- Fire view: 2-sided
- Fuel: Natural gas, Propane
- Suitable for new natural gas: yes
- Combustion system: Combustion air from outside
- Glass window: Standard glass
- Door type: Fixed door
- Control: Remote control RCH DRU, Smartphone/tablet
- Control hatch: optional
- Burner: Vario Burner*
- Eco Wave: yes
- Thermostat: yes
- Colours: Black
- Material: Steel
- Interior: Black, Ceraglass
- Fire bed: Brown logs
- Efficiency (%): 91.0
- Built-in depth (mm): 460
- Fire view width (mm): 766
- Fire view height (mm): 440
- Weight (kg): 95
- Vertical pipe length min
- Flue Ø (mm): 150/100
- PowerVent possible : yes
Included in the scope of delivery:
Ceramic imitation logs, brown
Shielding box no. 1076621 electrical protective housing for floating installation on a plateau
Gas fitting and receiver for remote control integrated in the appliance
RCH remote control The DRU Lugo 80/3 Eco Wave is therefore not only a visual highlight, but also an efficient and environmentally friendly heating solution for modern living spaces.
Optional accessories:
- Communication module for WiFi
- Support frame
- Mounting frame 6-sided
- Set of 4 feet (L:25 x W:25 x H:490 mm)
- Set of 4 supports for plateau
- Service door
- Gas hose for gas socket - pre-assembled
Important information
230 V electrical connection required!
Please note additional components for orders with PowerVent! (on request)
Installation panel - can be ordered as an option - standard panel included in the scope of delivery
The cover is an optical design element and is not a supporting frame!
The technical details of DRU gas fire inserts cover a wide range of aspects that are relevant for both semi-automatic and fully automatic operation. Here is a summary of the technical description:
Honeywell control (RCH)
- Fully automatic operation: Requires a 230 V power connection.
- WiFi module: A communication module for control via mobile device (Android/iOS) via WLAN can be integrated as an option.
- Radio remote control: Includes the following functions:
- Ignition
- 15-stage flame adjustment (up to 30-stage for double burners)
- On/off (no pilot light required, saves gas)
- Daily and weekly programme via timer
- Programmable thermostat presets
- EcoWave activation.
*Vario burner
- A rich flame pattern with plenty of perspective
- The adaptation of the wood fire: wide and high flames
- Multiple dimensions thanks to the unique zigzag shape
Technical equipment
- Adjustable feet: The factory-installed feet can be adjusted by 50 mm. Optional adjustable feet are available with a height of up to 490 mm.
- Front design: Frameless glass ceramic panel, the gas fire insert may only be operated when closed.
- Burner granulate: Vermiculite is used as burner granulate.
- Imitation wood: Fire-resistant imitation wood made of ceramic fibre. Some models are also available with Carrara or Greystone stones.
- LAS system: Every gas fire insert must be connected to a DRU LAS system.
Control and regulation unit
- Supplied pre-assembled in a control box that can be positioned individually in the base area of the system.
- Connection lines for ignition, flame detector and gas line are usually located in the centre, on some models also on the left.
Accessories & instructions
- The installation and operating instructions are included in the scope of delivery.
- Accessories such as a control box (not included as standard with Lugo models) are available separately.
All in all, DRU gas fire inserts offer a high degree of flexibility in control and installation, precise flame control and modern additional functions for convenience and energy efficiency.
Important note: The connection of a gas fire must ONLY be carried out by a specialist company!
DRU gas fires may ONLY be installed with the DRU LAS flue gas system; otherwise they are not certified and will not be approved.
Shipping conditions
Delivery is only possible within Germany.Other countries only on request; pick up is also possible!
Shipping costs (including statutory VAT)
Deliveries within Germany:
We calculate the shipping costs based on the order value (gross goods value):
up to a goods value of 99.99 EUR = 6.90 EUR
free shipping within Germany from a goods value of 100 EUR
Manufacturer: Spartherm Feuerungstechnik GmbH
Maschweg 38
D-49324 Melle
Tel.: +49 5422 9441-0
www.spartherm.com
Maschweg 38
D-49324 Melle
Tel.: +49 5422 9441-0
www.spartherm.com
Protective measures/safety instructions during installation
The following protective measures and safety instructions must be strictly observed:
- Installation and maintenance of the appliance may only be carried out by a recognized and competent installer in the field of gas heating and electricity.
- No modifications may be made to the appliance.
- Only use the flue gas extraction/combustion air supply system supplied by DRU.
- Procedure for installing a freestanding appliance: place the appliance at the specified minimum distance from the rear wall (see the information later in this text).
- Do not cover the appliance or wrap it in an insulating blanket or other materials. Ensure that there are no flammable objects and/or materials in the radiation area of the appliance. This radiation range is 500 mm, unless otherwise specified.
- Only use the set included in the scope of delivery, for example the wooden block set or the pebble set, and place it exactly as described.
- Leave the space around the ionizing pin and the ignition pin free and never place any incandescent material around these pins.
- Make sure that the gas pipes and connections are clean and free of any impurities. Install a gas tap in accordance with the applicable regulations.
- Check the entire system for gas leaks before commissioning.
- Make sure that the pressure equalization hatch(es) on the top and/or bottom of the appliance are not blocked and check that these hatch(es) are well connected to the sealing surface before installing the appliance.
- Do not ignite the appliance until it has been fully installed in terms of gas technology, exhaust technology and electrical technology; first go through the procedure described in chapter 7.3 of the instructions.
- Do not use the appliance if a pane is broken and/or cracked. The pane must be replaced first.
Procedure for installing a built-in appliance:
- Use fireproof and heat-resistant materials for the fireplace surround, including the top of the fireplace surround and the material inside the fireplace surround, such as the floor under the appliance and the rear wall in front of which the appliance is installed. Both panel materials and stone-like materials can be used for this purpose.
- Take appropriate protective measures to ensure that the wall behind the fireplace surround and the materials or objects located behind the rear wall do not heat up too much.
- Observe the minimum specifications regarding the internal dimensions of the fireplace surround. These have been specified for safety reasons and to avoid extreme heat build-up in the fireplace conversion.
- Ventilate the fireplace conversion using ventilation openings (see instructions). These openings are crucial for safety and to prevent extreme heat build-up in the fireplace conversion.
- The electrical connections must be heat-resistant.
- Position the heat-resistant power connections away from the appliance and as low as possible in the fireplace surround.
- This applies in connection with the temperature development in the fireplace surround.
The appliance is designed to create a cozy atmosphere and to heat. This means that all visible surfaces, including the glass, can become hotter than 100°C. It is recommended to always place a protective grille in front of the appliance if children, the elderly or the physically disabled are in the same room as the appliance. If vulnerable persons may regularly be present in the room without supervision, a fixed screen must be fitted around the appliance.